{"product_id":"qhyccd-600ph-c-sbfl-qhy600ph-c-sbfl","title":"QHY600M\/C Cooled Photographic Camera","description":"\u003ch2\u003eQHYCCD 600M\/C Photographic Camera\u003c\/h2\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003cp style=\"text-align: left;\"\u003eEquipped with a Sony IMX455, the QHY600 is a back-illuminated Scientific CMOS Camera with extremely low dark current (0.002e\/p\/s@-20C) using SONY’s Exmor BSI CMOS technology. QHY600 is also a zero amplifer glow camera.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eThe QHY600 has only one electron of read noise at high gain and full resolution and 4FPS readout speed.  One electron of read noise means the camera can achieve a SNR\u0026gt;3 at only 4 to 6 photons. This is perfect performance when conditions are photon limited, i.e., short exposures, narrow band imaging, etc., making this large area sensor ideal for sky surveys, time domain astronomy, fluorescence imaging, DNA sequencing and microscopy.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003e2GB DDR3 image buffer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210414707.png\"\u003e\u003cimg height=\"281\" width=\"600\" src=\"https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210414707.png\" alt=\"\" sizes=\"(max-width: 600px) 100vw, 600px\" srcset=\"https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210414707.png 1920w, https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210414707-768x360.png 768w, https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210414707-1536x720.png 1536w\" class=\"lazyloaded\" data-ll-status=\"loaded\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eIn order to provide smooth uninterrupted data transfer of the entire 60MP sensor at high speed, the QHY600 has 2GB DDR3 image buffer. The pixel count of the latest generation of CMOS sensors is very high resulting in greater memory requirements for temporary and permanent storage.  For example, the QHY600 sensor produces about 120MB of data per frame.  The data band-width is also increased from the original 16-bits to the current 32-bits.  Transferring such a large file sizes necessarily requires the camera to have sufficient memory. The QHY600 has adopted a large-capacity memory of up to 2GB.  Data throughput is doubled. This large image buffer meets the needs of high-speed image acquisition and transmission of the new generation of CMOS, making shooting of multiple frames smoother and less stuttered, further reducing the pressure on the computer CPU.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eAnother advantage is that when using some computers that do not have fast processors or have poor support for USB 3.0, the computer can’t transfer high-speed data well, and the data is often lost. The DDR can buffer a lot of image data and send it to the computer. Even if the USB 3.0 transmission frequently gets suspended, it will ensure that data is not lost. There are options in SharpCap to turn DDR buffering on or off. The current version of the ASCOM driver works in DDR mode.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003eExtended Full Well Capacity and Multiple Read Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eWith a pixel size of 3.76um, these sensors already have an impressive full well capacity of 51ke.  Nevertheless, QHYCCD has implemented a unique approach to achieve a full well capacity higher than 51ke- through innovative user controllable read mode settings.  In extended full well readout mode, the QHY600 can achieve an extremely large full-well charge value of nearly 80ke- and the QHY268C can achieve nearly 75ke-.  Greater full-well capacity provides greater dynamic range and large variations in magnitude of brightness are less likely to saturate.  The QHY600 \/ 268C have three readout modes with different characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"155\" width=\"519\" style=\"float: none;\" src=\"https:\/\/www.qhyccd.com\/uploadfile\/2020\/0222\/20200222073624670.png\" data-cke-saved-src=\"https:\/\/www.qhyccd.com\/uploadfile\/2020\/0222\/20200222073624670.png\" class=\"lazyloaded\" data-ll-status=\"loaded\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210602255.png\"\u003e\u003cimg height=\"50\" width=\"50\" src=\"https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210602255.png\" alt=\"\" class=\"lazyloaded\" data-ll-status=\"loaded\"\u003e\u003c\/a\u003e\u003cstrong\u003eNative 16 bit A\/D:\u003c\/strong\u003e The new Sony sensor has native 16-bit A\/D on-chip. The output is real 16-bits with 65536 levels. Compared to 12-bit and 14-bit A\/D, a 16-bit A\/D yields higher sample resolution and the system gain will be less than 1e-\/ADU with no sample error noise and very low read noise.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210602659.png\"\u003e\u003cimg height=\"50\" width=\"50\" src=\"https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210602659.png\" alt=\"\" class=\"lazyloaded\" data-ll-status=\"loaded\"\u003e\u003c\/a\u003e\u003cstrong\u003eBSI:\u003c\/strong\u003e One benefit of the back-illuminated CMOS structure is improved full well capacity. This is particularly helpful for sensors with small pixels. In a typical front-illuminated sensor, photons from the target entering the photosensitive layer of the sensor must first pass through the metal wiring that is embedded just above the photosensitive layer. The wiring structure reflects some of the photons and reduces the efficiency of the sensor. In the back- illuminated sensor the light is allowed to enter the photosensitive surface from the reverse side. In this case the sensor’s embedded wiring structure is below the photosensitive layer. As a result, more incoming photons strike the photosensitive layer and more electrons are generated and captured in the pixel well. This ratio of photon to electron production is called quantum efficiency. The higher the quantum efficiency the more efficient the sensor is at converting photons to electrons and hence the more sensitive the sensor is to capturing an image of something dim.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210602540.png\"\u003e\u003cimg height=\"50\" width=\"50\" src=\"https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210602540.png\" alt=\"\" class=\"lazyloaded\" data-ll-status=\"loaded\"\u003e\u003c\/a\u003e\u003cstrong\u003eZero Amplify Glow:\u003c\/strong\u003e This is also a zero amplifer glow camera.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210602542.png\"\u003e\u003cimg height=\"50\" width=\"50\" src=\"https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210602542.png\" alt=\"\" class=\"lazyloaded\" data-ll-status=\"loaded\"\u003e\u003c\/a\u003e\u003cstrong\u003eTRUE RAW Data: \u003c\/strong\u003eIn the DSLR implementation there is a RAW image output, but typically it is not completely RAW.  Some evidence of noise reduction and hot pixel removal is still visible on close inspection.  This can have a negative effect on the image for astronomy such as the “star eater” effect.  However,  QHY Cameras offer TRUE RAW IMAGE OUTPUT and produces an image comprised of the original signal only, thereby maintaining the maximum flexibility for post-acquisition astronomical image processing programs and other scientific imaging applications.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210602234.png\"\u003e\u003cimg height=\"50\" width=\"50\" src=\"https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210602234.png\" alt=\"\" class=\"lazyloaded\" data-ll-status=\"loaded\"\u003e\u003c\/a\u003e\u003cstrong\u003eAnti-Dew Technology: \u003c\/strong\u003eBased on almost 20-year cooled camera design experience, The QHY cooled camera has implemented the fully dew control solutions. The optic window has built-in dew heater and the chamber is protected from internal humidity condensation. An electric heating board for the chamber window can prevent the formation of dew and the sensor itself is kept dry with our silicon gel tube socket design for control of humidity within the sensor chamber.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"50\" width=\"50\" src=\"https:\/\/www.qhyccd.com\/wp-content\/uploads\/20210602302.png\" alt=\"\" class=\"lazyloaded\" data-ll-status=\"loaded\"\u003e\u003cstrong\u003eCooling:\u003c\/strong\u003e In addition to dual stage TE cooling, QHYCCD implements proprietary technology in hardware to control the dark current noise.\u003c\/p\u003e\n\u003ch4\u003eModels\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eQHY600 Series have mutiple models which covers both photographic and scientific using. Below list different types of QHY600 PH (photographic) series:\u003c\/p\u003e\n\u003cp\u003eQHY600PH : Standard version for amateur astrographers;\u003c\/p\u003e\n\u003cp\u003eQHY600PH SBFL : it has shorter back focal length compared with other PH types;\u003c\/p\u003e\n\u003cp\u003eQHY600PH L : a Lite, shorter and cheaper version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv id=\"c110\"\u003eQHY600PH SBFL\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cimg height=\"266\" width=\"400\" src=\"https:\/\/www.qhyccd.com\/uploadfile\/2020\/0622\/20200622014410577.jpg\" alt=\"\" data-cke-saved-src=\"https:\/\/www.qhyccd.com\/uploadfile\/2020\/0622\/20200622014410577.jpg\" class=\"lazyloaded\" data-ll-status=\"loaded\"\u003e\u003c\/p\u003e\n\u003cp\u003eQHY600PH-SBFL (Short back-focal length version) is specially designed for DSLR lens users or those who has special requirment of short back focal length. This version has a special front part version which has 14mm B.F.L only*. The front part includes six M2.5 screw holes arranged on a 80mm diameter roundness. QHY600 SBFL can easily match Canon\/Nikon lens, even with filter wheel.\u003c\/p\u003e\n\u003cp\u003eQHY600 Short Back-focus version supports CAA function, too. However, each QHY camera guarantees the right center angle with professional devices before the sale. So please do not adjust CAA unless there’s a problem at the front of the cam, like telescope adapters.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg height=\"160\" width=\"241\" src=\"https:\/\/www.qhyccd.com\/uploadfile\/2020\/0622\/20200622014625247.png\" alt=\"\" data-cke-saved-src=\"https:\/\/www.qhyccd.com\/uploadfile\/2020\/0622\/20200622014625247.png\" class=\"lazyloaded\" data-ll-status=\"loaded\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003eOn the side of this adapter there is a 4mm hole to connect air pump through plastic pipe in case of the  dewing glass when necessary.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"162\" width=\"243\" src=\"https:\/\/www.qhyccd.com\/uploadfile\/2020\/0622\/20200622014001462.jpg\" alt=\"\" data-cke-saved-src=\"https:\/\/www.qhyccd.com\/uploadfile\/2020\/0622\/20200622014001462.jpg\" class=\"lazyloaded\" data-ll-status=\"loaded\"\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"994\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eQHY600PH SBFL (Short Back Focal Length Version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eCMOS Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eSONY IMX455\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eMono\/Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eBoth Available (while Mono only with QHY600PH-L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eFSI\/BSI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eBSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003ePixel Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003e3.76um x 3.76um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eEffective Pixel Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003e9576*6388\n\u003cp\u003e（9600*6422 with overscan and optically black area)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eEffective Pixels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003e61.17 Megapixels\u003cbr\u003e(effective area.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eSensor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eFull Frame 36mm x 24mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\n\u003cstrong\u003eA\/D Sample Depth\u003c\/strong\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"435\"\u003e16-bit (0-65535 levels) at 1X1 binning\n\u003cp\u003e18-bit at 2X2, 19-bit at 3X3, 20-bit at 4X4 software binning\u003c\/p\u003e\n\u003cp\u003e*QHY600 uses the software digital binning for 2*2binning. With digital sum, 2*2binning will be four 16-bit summed then it is 18-bit.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eFull Well Capacity (1×1, 2×2, 3×3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eStandard Mode\u003cbr\u003e\u0026gt;51ke-  \/ \u0026gt;204ke- \/ \u0026gt;408ke-\u003cbr\u003eSuper Full Well Mode\u003cbr\u003e\u0026gt;80ke-  \/ \u0026gt;320ke- \/ \u0026gt;720ke-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eFull Frame Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eUSB3.0 Port Image Transfer Speed\n\u003cp\u003eFull Frame Size: 4.0FPS (8-bit output)\u003c\/p\u003e\n\u003cp\u003eFull Frame Size: 2.5FPS (16-bit output)\u003c\/p\u003e\n\u003cp\u003e7.2FPS at 9600×3194, 22.5FPS at 9600×1080, 28FPS at 9600×768, 47FPS at 9600×480, 160FPS at 9600×100,\u003c\/p\u003e\n\u003cp\u003eFiber Port Image Transfer Speed (QHY600Pro only)\u003c\/p\u003e\n\u003cp\u003eFull Frame Size: 4.0FPS (16-bit output)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eReadout Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003e1.0e- to 3.7e-  (Standard Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eDark Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003e0.0022e-\/p\/s @ -20C    0.0046e-\/p\/s @ -10C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eExposure Time Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003e40us – 3600sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eUnity Gain*\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003e25 (Extended Full Well Mode) *\n\u003cp\u003e*With the improvement of the CMOS technology, the 16bit CMOS camera has been released, like QHY600\/268\/411\/461. For these cameras, even in lowest gain it has beyond the requirement of unit gain (less than 1e\/ADU due to sufficient samples) So you can directly set gain 0 as start. Please note QHY600\/268C\/411\/461 has extend full well mode. In this mode you still need to find out the unit gain position.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eAmp Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eZero Amplifer Glow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eFirmware\/FPGA remote Upgrade\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eSupported. Via Camera USB Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eShutter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eElectric Rolling Shutter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eComputer Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eUSB3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eBuilt-in Image Buffer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eDDR3 memory\n\u003cp\u003ePH \u0026amp; PH SBFL ver.: 2GBytes（16Gbit）\u003cbr\u003eLite ver. : 1GBytes（8Gbit）\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eHardware Frame Sequence Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eCooling System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eDual Stage TEC cooler:\u003cbr\u003e– Long exposures (\u0026gt; 1 second) typically -35C below ambient\u003cbr\u003e– Short exposure (\u0026lt; 1second) high FPS, typically -30C below ambient（Test temperature +20°）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eOptic Window Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eAR+AR High Quality Multi-Layer Anti-Reflection Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eAnti-Dew Heater\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eTelescope Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eM54\/0.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eBack Focal Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003eQHY600PH\u0026amp;QHYPH-L: 17.5mm+6mm (±0.2)\n\u003cp\u003eQHY600SBFL: 14.5mm*\u003c\/p\u003e\n\u003cp\u003e*The BFL Consumed equals 12.5mm when connecting QHYCFW. About the defination of “BFL Comsumed” and our adapter system please view: https:\/\/www.qhyccd.com\/adapters\/\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003eWeigth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003ePH Version: 850g\u003cbr\u003eLite Version: 790g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"161\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"435\"\u003e40W\/100%\u003cbr\u003e20W\/50%\u003cbr\u003e13.8W\/0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIn the Box\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eCamera\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCables\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eManual \u0026amp; Warranty\u003c\/h3\u003e\n\u003cp\u003eQHYCCD 2-Years Warranty\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"QHYCCD","offers":[{"title":"QHY600C-PH (Color)","offer_id":46326670655717,"sku":null,"price":6531.0,"currency_code":"CAD","in_stock":true},{"title":"QHY600M-PH (Mono)","offer_id":46326670688485,"sku":null,"price":6531.0,"currency_code":"CAD","in_stock":true},{"title":"QHY600C-PH Short BFL (Color)","offer_id":43708303343845,"sku":"QHY-QHY600C-PH-SBFL","price":6531.0,"currency_code":"CAD","in_stock":true},{"title":"QHY600M-PH Short BFL (Mono)","offer_id":43708303311077,"sku":"QHY-QHY600M-PH-SBFL","price":6531.0,"currency_code":"CAD","in_stock":true},{"title":"QHY600M-PH-SBFL+CFW3L","offer_id":43712513245413,"sku":"QHY-QHY600M-PH-SBFL-COMBO2","price":6973.0,"currency_code":"CAD","in_stock":true},{"title":"QHY600M-PH-SBFL+CFW3L+OAGM-Pro","offer_id":44396994855141,"sku":"QHY-QHY600M-PH-SBFL-COMBO3","price":7257.0,"currency_code":"CAD","in_stock":true},{"title":"QHY600M-PH-SBFL+CFW3XL+OAGL-Pro","offer_id":43712513212645,"sku":"QHY-QHY600M-PH-SBFL-COMBO1","price":7853.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/6245\/2965\/files\/qhy600ph-mc-sbfl-cooled-photographic-camera-astronomy-plus-1.webp?v=1690488232","url":"https:\/\/istronomyplus.com\/products\/qhyccd-600ph-c-sbfl-qhy600ph-c-sbfl","provider":"Astronomy Plus – Telescopes \u0026 Astrophotography Canada","version":"1.0","type":"link"}